Search
Submit
Cancel
CARLYI
News Center
/
/
Repair and maintenance of Ac condenser fan motor

Products Center

Contact Us

Repair and maintenance of Ac condenser fan motor

  • Categories:News
  • Author:
  • Origin:
  • Time of issue:2021-02-02
  • Views:0

(Summary description)Ac condenser fan motor and the electric heating tube of the air cooler are a vulnerable part.

Repair and maintenance of Ac condenser fan motor

(Summary description)Ac condenser fan motor and the electric heating tube of the air cooler are a vulnerable part.

  • Categories:News
  • Author:
  • Origin:
  • Time of issue:2021-02-02
  • Views:0
Information

Ac condenser fan motor and the electric heating tube of the air cooler are a vulnerable part. The fan motor that runs for a long time in a high temperature environment may malfunction and be damaged. If the temperature of the cold storage is very important, you must order some vulnerable parts to facilitate timely maintenance.

Ac condenser fan motor's ambient temperature problem. Ac condenser fan motor is generally installed on the roof of the outdoor building. In the environment with high temperature in summer, the temperature of the condenser itself is very high, which increases the operating pressure of the unit. If there is a lot of hot weather, you can add a pergola on the roof condensation to block the sun and reduce the temperature of the condenser to reduce the pressure of the machine, protect the unit equipment, and ensure the temperature of the cold storage. Of course, if the unit capacity is sufficient to ensure the storage temperature, it is not necessary to build a pergola.

The electric heating pipe of the air cooler also needs spare parts to be more safe. The installation of refrigeration system equipment and refrigerant pipelines, even the overall design of the cold storage and the daily use of the cold storage, must be done in strict accordance with the specifications. Any irregular design, installation or use or maintenance will cause the refrigeration system to operate Defects, and even cause malfunction and damage to the machine.

Of course, no matter what motor we are in, we need to repair and maintain the equipment. Today we will learn about how to repair and maintain the Ac condenser fan motor!

1.During the operation of the Ac condenser fan motor, it is found that the fan has abnormal noise, the motor is seriously heated, the shell is electrified, the switch is tripped, and it cannot be started. It should be shut down immediately for inspection. In order to ensure safety, maintenance is not allowed during the operation of the fan. After the maintenance, a test run should be carried out for about five minutes to confirm that there is no abnormal phenomenon before starting the operation.

2.Ac condenser fan motor should be stored in a dry environment to prevent the motor from getting damp. When the AC cooling fan is stored in the open air, there should be defensive measures. During storage and transportation, the AC cooling fan should be prevented from bumping to avoid damage to the fan.

3.The AC condenser fan motor can only be operated under normal conditions. At the same time, it is necessary to ensure that the capacity of the power supply facilities is sufficient, the voltage is stable, and it is strictly forbidden to operate without phase.

4.The AC condenser fan motor should always be kept tidy in the use environment, the surface of the fan should be kept clean, there should be no debris in the inlet and outlet, and the dust and other debris in the fan and pipe should be cleaned regularly.

5.According to the operating environment conditions, the bearing should be supplemented or replaced with lubricating grease from time to time. It is not necessary to replace the lubricating grease for the enclosed bearing of Ac condenser fan motor during the service life. There are corresponding requirements, so that the bearings and motor bearings can be sealed, and professional grease should be used to fill the inner and outer rings of the bearing, and it is strictly forbidden to run without oil.

Keyword:

Scan the QR code to read on your phone

Related News

Precautions

Precautions for Brushless DC motor products when replacing the brushes

Brushless DC motor products are mainly composed of three parts: the motor body, the electronic switch circuit and the rotor position sensor. Among them, the DC power supply supplies power to the stator windings of the motor through the electronic switch circuit.
2021-10-12
Analysis

Analysis of Brushless DC Motor Products' Moisture Treatment Methods

Brushless DC motor products are widely used in appliances and instruments such as daily life appliances, automotive industry, aviation, consumer electronics, industrial automation and so on.
2021-10-09
90-550W

90-550W heat pump ac fan motor manufacturer will show you the internal structure of AC fan

The 90-550W heat pump ac fan motor manufacturer tells you that the internal structure of an AC fan (single-phase) consists of two coil groups, one of which is a winding and the other is a running winding.
2021-09-27
The

The 90-550W heat pump ac fan motor manufacturer will show you that there are so many differences between DC fans and AC fans

The 90-550W heat pump ac fan motor manufacturer tells you that with the improvement of people's living standards, there are more and more fans of all kinds, including civilian and industrial ones.
2021-09-22

Feedback

留言应用名称:
客户留言
描述:
CARLYI

National unified free hotline:

Tel : +86 0519-85609859
Fax : +86 0519-85609859
E-mail :
chenyifei@carlyi.com
Address : No. 26, Donggang 2nd Road, Binjiang Economic Development Zone, Xinbei District, Changzhou

Changzhou Carlyi Electric Co., Ltd.苏ICP备2021002841号-1  Powered by www.300.cn